OSBURN 2000 WOOD STOVE WITH BLOWER

Year after year, the 2000 model remains one of the most popular wood stoves in the Osburn range.

In 2018, Osburn redefines the design of this heating appliance and sets new standards for emissions. This new version keeps its 2.4 cubic foot combustion chamber and still offers the same power with an impressive emission performance of around 1.54 g/h. With this model, the 130 CFM fan is still included; unquestionably the best opportunity this season!

Its new cast iron door gives a youthful look with elegant lines while retaining the spirit of wood heating. Customize your appliance to suit your décor: refined door overlays, new leg designs, glass ash lip with integrated ash pan; significant innovations for the most seasoned experts.

Category:

Description

Fuel type : Dry cordwood
Heating area : 500 – 2,100 Ft2
Maximum heat output : 75,000 BTU/h (22.0 kW)

APPLIANCE PERFORMANCE

APPLIANCE PERFORMANCE (1)

Fuel type : Dry cordwood
Recommended heating area (sq.ft.) : () 500 – 2,100
Overall firebox volume : 2.4
Maximum burn time : () 8h
Maximum heat output (dry cordwood) : (2) 75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.) : (2) (3) 14,800 BTU/h (4.34 kW) to 28,600 BTU/h (8.38 kW)
Average overall efficiency (EPA cribs / Douglas fir) : (3) N.A. (HHV) (4) N.A. (LHV) (5)
Average overall efficiency (dry cordwood) : (3) 69 % (HHV) (4) 74 % (LHV) (5)
Optimum efficiency : (6) (7) 77 %
Average particulate emissions rate : (8) 1.54 g/h
Average CO : (9) 89.4 g/h

(1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

(2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.

(3) As measured per CSA B415.1-10 stack loss method.

(4) Higher Heating Value of the fuel.

(5) Lower Heating Value of the fuel.

(6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.

(7) Optimum overall efficiency at a specific burn rate (LHV).

(8) This appliance is officially tested and certified by an independent agency.

(9) Carbon monoxyde.

GENERAL FEATURES

GENERAL FEATURES

Combustion technology Non-catalytic
High-efficiency EPA certified appliance Yes, EPA 2020 approved
Maximum log length 20″
Log positioning Over width
Chimney diameter 6″
Flue outlet diameter 6″
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Minimum chimney height (feet) 12′
Baffle type C-Cast
Approved for an alcove installation Yes
Approved for a mobile home installation Yes, with fresh air intake
Shipping Weight 390 lb (177 kg)
Door type Single, glass with cast iron frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 17 1/8″ X 10 1/4″
Glass air-wash system Yes
Premium quality blower included (CFM) 130
Overall dimension (Height) 33 1/8″
Overall dimension (Width) 27″
Overall dimension (Depth) 29″
Door opening – dimension (Height) 9″
Door opening – dimension (Width) 17 1/2″
Firebox – dimension (Height) 11 7/8″
Firebox – dimension (Width) 21″
Firebox – dimension (Depth) 16 3/4″
Firebox lined with refractory bricks for better heat distribution Yes
Stainless-steel secondary-air system improving gas combustion Yes
Model Legs or pedestal
Steel thickness – body 3/16″
Steel thickness – top 5/16″
Easy-to-access ash drawer Yes
USA standard (emissions) Comply with EPA 2020
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1482, UL 737
Canadian standard (safety) ULC S627
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime
Minimum clearances to combustibles*
(Data expressed in inches. 1 inch = 25.4 mm)
Canada United-States
Single wall pipe Double wall pipe Single wall pipe Double wall pipe
Clearance – back wall 14 ½” 6″ 11″ 6″
Clearance – placed in a corner 10″ 7″ 10″ 7″
Clearance – side wall 17″ 17″ 16″ 16″
Clearance – top (measured from the platform on which the appliance is installed)** 84″ 84″ 84″ 84″

* The information given on the certification label affixed to the appliance always overrides the information published in any other media (owner’s manual, catalogues, flyers, magazines and/or web sites).

** Some appliances have been tested with a low ceiling. Before setting up your unit, refer to the installation manual.